Restrictive flow orifice
A restrictive flow orifice is a type of orifice plate. They are used to limit the potential danger, damage, or wastage of an uncontrolled flow from, for example, a compressed gas cylinder They are generally not limiting the flow during normal operation but if a fault or failure occurs causing uncontrolled flow the orifice will present a restriction, limiting the flow. It may be used to limit the accidental release of a hazardous gas resulting from regulator or other component failure, restricting flow in a system in order to assure adequate pressure relief valve sizing and system over pressure protection, or restricting flow from bulk sources such as a water main.
Predicting Flow
Correlations assist in predicting the flow of a particular gas or gas mixture through a RFO. This is done by first determining theflow through the same RFO at the required pressure with a reference gas and then adjusting the specific gravity accordingly.
The pertinent equation for the reference gas of nitrogen is presented below.