Owen Falls
The Owen Falls was a waterfall on the White Nile in Uganda near the city of Jinja. The falls, together with the nearby Ripon Falls, were submerged in 1954 with the completion of the Nalubaale Hydroelectric Power Station. The dam that houses the power station was originally named Owen Falls Dam, but was later renamed Nalubaale Dam and the name of the power station was also changed, from Owen Falls Power Station to Nalubaale Power Station.
Location
The waterfalls were located approximately, north, of the point where the river leaves Lake Victoria. This is the location of Nalubaale Dam, previously called Owen Falls Dam. The geographical location of the former Owen Falls are:00°26'37.0"N, 33°11'05.0"E.The power station
The original Owen Falls Power Station consisted of a concrete gravity dam with a close coupled intake powerhouse unit. It controls the Lake Victoria outflows through a series of ten turbines and six sluices in the dam. When fully opened, the six sluices provide a spill capacity of about1,200 cubic metres per second.
At the time of its commissioning by Queen Elizabeth II, in 1954, the power station had two units of 15 megawatts each, for generation capacity of 30 megawatts. The table below illustrates how generation capacity was gradually increased until all ten units were operational in 1968. That year, generation capacity at the power station reached 150 megawatts.
| Rank | Year | Active Units | Unit Capacity | Total Capacity | Notes |
| 1 | 1954 | 2 | 15 Megawatts | 30 Megawatts | |
| 2 | 1955 | 4 | 15 | 60 | |
| 3 | 1957 | 6 | 15 | 90 | |
| 4 | 1958 | 7 | 15 | 105 | |
| 5 | 1959 | 8 | 15 | 120 | |
| 6 | 1966 | 9 | 15 | 135 | |
| 7 | 1968 | 10 | 15 | 150 | |
| 8 | 1996 | 10 | 18 | 180 | |
| Total | 10 | 18.00 | 180.00 |
Operations and upgrade
According to agreements between the Colonial British government and the government of Egypt, signed in 1929 and amended in 1949, the power station is operated through the Agreed Curve, so that the outflow from Lake Victoria remains the same as it wasbefore the construction of the dam; when the outflow from the lake was naturally controlled by the rocky barrier of mukkibi falls.
Due to neglect and lack of maintenance from 1971 until 1986, generation capacity at Owen Falls Dam deteriorated to 60 megawatts by 1986. This required repairs and rehabilitation, including the increase of each turbine's capacity from 15 megawatts to 18 megawatts, to meet demand. The power station's generation capacity reached 180 megawatts in 1996.