Lung compliance
Lung compliance, or pulmonary compliance, is a measure of the lung's ability to stretch and expand. In clinical practice it is separated into two different measurements, static compliance and dynamic compliance. Static lung compliance is the change in volume for any given applied pressure. Dynamic lung compliance is the compliance of the lung at any given time during actual movement of air.
Low compliance indicates a stiff lung and can be thought of as a thick balloon – this is the case often seen in fibrosis. High compliance indicates a pliable lung and can be thought of as a grocery bag – this is the case often seen in emphysema. Compliance is highest at moderate lung volumes, and much lower at volumes which are very low or very high. The compliance of the lungs demonstrate lung hysteresis; that is, the compliance is different on inspiration and expiration for identical volume.
Calculation
Pulmonary compliance is calculated using the following equation, where ΔV is the change in volume, and ΔP is the change in pleural pressure:For example, if a patient inhales 500 mL of air from a spirometer with an intrapleural pressure before inspiration of −5 cm H2O and −10 cm H2O at the end of inspiration. Then:
Static compliance (''C''stat)
Static compliance represents pulmonary compliance during periods without gas flow, such as during an inspiratory pause. It can be calculated with the formula:where
Pplat is measured at the end of inhalation and prior to exhalation by using an inspiratory hold maneuver. During this maneuver, airflow is transiently discontinued, which eliminates the effects of airway resistance. Pplat is never bigger than PIP and is typically <10 cm H2O lower than PIP when airway resistance is not elevated.
Dynamic compliance (''C''dyn)
Dynamic compliance represents pulmonary compliance during periods of gas flow, such as during active inspiration. Dynamic compliance is always lesser than or equal to static lung compliance because PIP − PEEP is always greater than Pplat − PEEP. It can be calculated using the following equation,where
Alterations in airway resistance, lung compliance and chest wall compliance influence Cdyn.
Dimensionality and physical analogues
The dimensions of compliance in respiratory physiology are inconsistent with the dimensions of compliance in physics-based applications. In physiology,whereas in newtonian physics, compliance is defined as the inverse of the elastic stiffness constant k,
Pulmonary compliance is analogous to capacitance.
Clinical significance
Lung compliance is an important measurement in respiratory physiology.- Decreased pulmonary compliance may be associated with fibrosis.
- Increased pulmonary compliance may be associated with COPD and emphysema due to loss of alveolar and elastic tissue.
Functional significance of abnormally high or low compliance
Low compliance indicates a stiff lung and means extra work is required to bring in a normal volume of air. This occurs as the lungs in this case become fibrotic, lose their distensibility and become stiffer.In a highly compliant lung, as in emphysema, the elastic tissue is damaged by enzymes. These enzymes are secreted by leukocytes in response to a variety of inhaled irritants, such as cigarette smoke. Patients with emphysema have a very high lung compliance due to the poor elastic recoil. They have extreme difficulty exhaling air. In this condition extra work is required to get air out of the lungs. In addition, patients often have difficulties inhaling air as well. In emphysema, loss of elastic recoil and alveolar interdependence promotes small-airway closure and regional Atelectasis, increasing closing volume and making inflation at low lung volumes more difficult. Compliance also increases with increasing age.
Both peak inspiratory and plateau pressure increase when elastic resistance increases or when pulmonary compliance decreases. On the other hand, only peak inspiratory pressure increases when airway resistance increases.
Compliance decreases in the following cases:
- Supine position
- Laparoscopic surgical interventions
- Severe restrictive pathologies
- Chronic restrictive pathologies
- Hydrothorax
- Pneumothorax
- High standing of a diaphragm
- Acute asthma attacks, where increased compliance also occurs for an unclear reason