Seismic retrofit


Seismic retrofitting is the modification of existing structures to make them more resistant to seismic activity, ground motion, or soil failure due to earthquakes. With better understanding of seismic demand on structures and with recent experiences with large earthquakes near urban centers, the need of seismic retrofitting is well acknowledged. Prior to the introduction of modern seismic codes in the late 1960s for developed countries and late 1970s for many other parts of the world, many structures were designed without adequate detailing and reinforcement for seismic protection. In view of the imminent problem, various research work has been carried out. State-of-the-art technical guidelines for seismic assessment, retrofit and rehabilitation have been published around the world – such as the ASCE-SEI 41 and the New Zealand Society for Earthquake Engineering 's guidelines. These codes must be regularly updated; the 1994 Northridge earthquake brought to light the brittleness of welded steel frames, for example.
The retrofit techniques outlined here are also applicable for other natural hazards such as tropical cyclones, tornadoes, and severe winds from thunderstorms. Whilst current practice of seismic retrofitting is predominantly concerned with structural improvements to reduce the seismic hazard of using the structures, it is similarly essential to reduce the hazards and losses from non-structural elements. It is also important to keep in mind that there is no such thing as an earthquake-proof structure, although seismic performance can be greatly enhanced through proper initial design or subsequent modifications.
Image:団地 support structure.jpg|thumb|205px|right| Reinforced by truss at 1st floor Condominium in Tokyo
Image:ExtReenfDetail.jpg|thumb|right|upright|External bracing of an existing reinforced concrete parking garage

Strategies

Seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials.
  • Increasing the global capacity. This is typically done by the addition of cross braces or new structural walls.
  • Reduction of the seismic demand by means of supplementary damping and/or use of base isolation systems.
  • Increasing the local capacity of structural elements. This strategy recognises the inherent capacity within the existing structures, and therefore adopts a more cost-effective approach to selectively upgrade local capacity of individual structural components.
  • Selective weakening retrofit. This is a counter-intuitive strategy to change the inelastic mechanism of the structure, while recognising the inherent capacity of the structure.
  • Allowing sliding connections such as passageway bridges to accommodate additional movement between seismically independent structures.
  • Addition of seismic friction dampers to simultaneously add damping and a selectable amount of additional stiffness.
Recently more holistic approaches to building retrofitting are being explored, including combined seismic and energy retrofitting. Such combined strategies aim to exploit cost savings by applying energy retrofitting and seismic strengthening interventions at once, hence improving the seismic and thermal performance of buildings.

Performance objectives

In the past, seismic retrofit was primarily applied to achieve public safety, with engineering solutions limited by economic and political considerations. However, with the development of Performance-based earthquake engineering, several levels of performance objectives are gradually recognised:
  • Public safety only. The goal is to protect human life, ensuring that the structure will not collapse upon its occupants or passersby, and that the structure can be safely exited. Under severe seismic conditions the structure may be a total economic write-off, requiring tear-down and replacement.
  • Structure survivability. The goal is that the structure, while remaining safe for exit, may require extensive repair before it is generally useful or considered safe for occupation. This is typically the lowest level of retrofit applied to bridges.
  • Structure functionality. Primary structure undamaged and the structure is undiminished in utility for its primary application. A high level of retrofit, this ensures that any required repairs are only "cosmetic" – for example, minor cracks in plaster, drywall and stucco. This is the minimum acceptable level of retrofit for hospitals.
  • Structure unaffected. This level of retrofit is preferred for historic structures of high cultural significance.

    Techniques

Common seismic retrofitting techniques fall into several categories:

External post-tensioning

The use of external post-tensioning for new structural systems have been developed in the past decade. Under the PRESS, a large-scale U.S./Japan joint research program, unbonded post-tensioning high strength steel tendons have been used to achieve a moment-resisting system that has self-centering capacity.
An extension of the same idea for seismic retrofitting has been experimentally tested for seismic retrofit of California bridges under a Caltrans research project and for seismic retrofit of non-ductile reinforced concrete frames. Pre-stressing can increase the capacity of structural elements such as beam, column and beam-column joints. External pre-stressing has been used for structural upgrade for gravity/live loading since the 1970s.

Base isolators

Base isolation is a collection of structural elements of a building that should substantially decouple the building's structure from the shaking ground thus protecting the building's integrity and enhancing its seismic performance. This earthquake engineering technology, which is a kind of seismic vibration control, can be applied both to a newly designed building and to seismic upgrading of existing structures.
Normally, excavations are made around the building and the building is separated from the foundations. Steel or reinforced concrete beams replace the connections to the foundations, while under these, the isolating pads, or base isolators, replace the material removed. While the base isolation tends to restrict transmission of the ground motion to the building, it also keeps the building positioned properly over the foundation. Careful attention to detail is required where the building interfaces with the ground, especially at entrances, stairways and ramps, to ensure sufficient relative motion of those structural elements.

Supplementary dampers

Supplementary dampers absorb the energy of motion and convert it to heat, thus damping resonant effects in structures that are rigidly attached to the ground. In addition to adding energy dissipation capacity to the structure, supplementary damping can reduce the displacement and acceleration demand within the structures. In some cases, the threat of damage does not come from the initial shock itself, but rather from the periodic resonant motion of the structure that repeated ground motion induces. In the practical sense, supplementary dampers act similarly to Shock absorbers used in automotive suspensions.

Tuned mass dampers

employ movable weights on some sort of springs. These are typically employed to reduce wind sway in very tall, light buildings. Similar designs may be employed to impart earthquake resistance in eight to ten story buildings that are prone to destructive earthquake induced resonances.

Slosh tank

A slosh tank is a large container of low viscosity fluid that may be placed at locations in a structure where lateral swaying motions are significant, such as the roof, and tuned to counter the local resonant dynamic motion. During a seismic event the fluid in the tank will slosh back and forth with the fluid motion usually directed and controlled by internal baffles – partitions that prevent the tank itself becoming resonant with the structure, see Slosh dynamics. The net dynamic response of the overall structure is reduced due to both the counteracting movement of mass, as well as energy dissipation or vibration damping which occurs when the fluid's kinetic energy is converted to heat by the baffles. Generally the temperature rise in the system will be minimal and is passively cooled by the surrounding air. One Rincon Hill in San Francisco is a skyscraper with a rooftop slosh tank which was designed primarily to reduce the magnitude of lateral swaying motion from wind. A slosh tank is a passive tuned mass damper. In order to be effective the mass of the liquid is usually on the order of 1% to 5% of the mass it is counteracting, and often this requires a significant volume of liquid. In some cases these systems are designed to double as emergency water cisterns for fire suppression.

Active control system

Very tall buildings, when built using modern lightweight materials, might sway uncomfortably in certain wind conditions. A solution to this problem is to include at some upper story a large mass, constrained, but free to move within a limited range, and moving on some sort of bearing system such as an air cushion or hydraulic film. Hydraulic pistons, powered by electric pumps and accumulators, are actively driven to counter the wind forces and natural resonances. These may also, if properly designed, be effective in controlling excessive motion – with or without applied power – in an earthquake. In general, though, modern steel frame high rise buildings are not as subject to dangerous motion as are medium rise buildings, as the resonant period of a tall and massive building is longer than the approximately one second shocks applied by an earthquake.

Ad hoc addition of structural support/reinforcement

The most common form of seismic retrofit to lower buildings is adding strength to the existing structure to resist seismic forces. The strengthening may be limited to connections between existing building elements or it may involve adding primary resisting elements such as walls or frames, particularly in the lower stories. Common retrofit measures for unreinforced masonry buildings in the Western United States include the addition of steel frames, the addition of reinforced concrete walls, and in some cases, the addition of base isolation.