Earl Wood
Earl Howard Wood was an American cardiopulmonary physiologist who helped invent the G-suit, brought heart catheterization into a clinical reality and introduced dynamic volumetric computed tomography for the study of the heart and lungs.
Career
G-suit
Shortly after receiving an M.D. and PhD in physiology from the University of Minnesota medical school under the mentorship of Professor Maurice B. Visscher, MD, Wood became a key member of a team, working in a laboratory at the Mayo Clinic, tasked with helping military pilots and flight crew survive and function in high G-force environments. Based upon extensive physiologic testing via use of the human centrifuge installed at the Mayo Clinic, it was determined that blackout and then unconsciousness was caused by reduction of blood flow to the eyes first and then the brain. The solutions the team arrived at were the M-1 breath hold maneuver and the G-suit. The M-1 maneuver consisted of a strained exhalation effort against a closed glottis designed to increase left ventricular pressure. The G suit was a garment, produced by the David Clark Company, which has air bladders situated at the calves, thighs, and abdomen of the wearer. The bladders inflate as the G-force acting on the aircraft increase, constricting the wearer's arteries, hence increasing blood pressure and blood flow to the brain.The G-suit was a superior solution to another alternative being tested at the time, which was considered impractically heavy and cumbersome. The water-filled, pulsatile pressure suits were developed to effect venous return. However, Wood and colleagues' detailed physiologic measurements demonstrated that what was required was augmentation of arterial pressure.
Wood himself regularly tested the flight suits, taking many turns in a human centrifuge and plane dubbed the "G-wiz". He calculated that during more than a thousand rides, he had lost consciousness for an aggregate of at least fifteen minutes. Wood was awarded a Presidential Certificate of Merit by Harry Truman in 1947.
The G-suit was adopted in the 1940s. The current models are based on the pattern Wood and his colleagues designed. Following World War II, Wood was recruited to participate in what was known as "Operation Paperclip" The goal was to keep the top German scientists away from Russia and working for the United States.
In 1962, Wood was the tenth scientist to be named "Career Investigator," of the American Heart Association. These funds allowed Wood considerable flexibility in regards to the directions of his research.
Other work
After his work on the G-Suit, Wood worked on techniques for measuring cardiac blood flow. He was granted a patent for the ear oximeter, an optical instrument that measures blood oxygen levels without taking blood by examining the variation of light absorption as a function of oxygen saturation of hemoglobin. Integral to the work leading to the development of the G suit was the perfection of vascular catheterization methods needed to understand the distribution of blood pressure and flow. Shortly after the end of World War II, open-heart surgery emerged with the Mayo contribution to the development of the heart-lung bypass machine initially developed by Gibbons and perfected by Wood and colleagues. Wood's work at the Mayo Clinic lead to the development of many technologies allowing for the assessment of the heart and lungs including dye dilution methods serving to characterize cardiac output, methods for the assessment of central blood volume, the calculation of pulmonary vascular resistance, analog subtraction angiography, and eventually the Dynamic Spatial Reconstructor, a predecessor to modern high speed volumetric computed tomography allowing for the evaluation of the beating heart and breathing lungs. The DSR comprised 14 X-ray tubes and a hemicylindrical fluorescent screen imaged by 14 associated television cameras.In all, Wood is noted for his contributions in the following areas:
- methods for protection against blackout and unconsciousness during high G-forces
- methods for heart catheterizations;
- methods for monitoring vascular pressures;
- the pulse oximeter for real time non-invasive monitoring or arterial oxygen saturation;
- methods for calculation of pulmonary vascular resistance ;
- methods for the digital conversion of analog physiologic signals allowing for computer-based monitoring of vascular signals ;
- methods for liquid fluorocarbon respiration explored for protection against high G forces expected during rocket launch and re-entry while leaving and returning to Earth's atmosphere in space exploration;
- methods for the assessment of pleural pressure to determine regional gravitational effects on the lung;
- indicator dilution curve methodology for the assessment of cardiac output and other physiologic derivative;
- indocyanine green dye for use in the indicator dilution method;
- analog subtraction angiography for the assessment of cardiac structures via video fluoroscopy and
- the earliest predecessor of modern high speed, multi-source / multi-detector row computed tomography for the non-invasive imaging of the beating heart and breathing lungs.