Bayswater Power Station
Bayswater Power Station is a bituminous (black) coal-powered thermal power station with one and three upgraded Tokyo Shibaura Electric steam driven turbo alternators for a combined capacity of. Commissioned between 1985 and 1986, the station is located from Muswellbrook, and from Singleton in the Hunter Region of New South Wales, Australia.
Prior to September 2014 Bayswater Power Station was part of NSW Government power producer, Macquarie Generation. Macquarie Generation was acquired by AGL Energy in September 2014 for $1,505 Million AUD.
History
The first generator was completed in 1985, and the remaining three generators progressively that same year and throughout 1986.Bayswater draws its cooling water from the Hunter River under water entitlements negotiated with the government of New South Wales. The Barnard River Scheme also allows Bayswater and Liddell to transfer water from the upper Manning River catchment into the Hunter River for their use, however in recent year's this system has not be utilised. All coal is supplied via the Antiene Train Unloader situated on the west side of Lake Liddell and transported to Bayswater's stockpiles by a long overland conveyor.
Coal consumption is around per annum and produces around of electricity a year. This is enough power for 2 million average Australian homes and families.
Greenhouse emissions
Carbon Monitoring for Action estimates this power station emits 19.80 million tonnes of greenhouse gases each year as a result of burning coal. In 2010 the Australian Government announced the introduction of a Carbon Pollution Reduction Scheme to help combat climate change. It is expected to impact on emissions from power stations. The National Pollutant Inventory provides details of a range of pollutant emissions, including CO, estimated at for the year ending 30 June 2024.In 2009, the power station was the subject of "the first ever legal action aimed at curbing greenhouse gas pollution from a coal-fired power station". Environmental activist Pete Gray went to the Land and Environment Court of New South Wales, asking it to find that the power station had been "wilfully or negligently disposing of waste by emitting carbon dioxide into the atmosphere in a manner that has harmed or is likely to harm the environment in contravention of section 115 of the Protection of the Environment Operations Act 1997", and sought an injunction against the station. The case, Gray and Anor v Macquarie Generation, was ongoing at the time of Gray's death from cancer in April 2011.
Mid-life upgrade
In December 2018, a proposed upgrade to the Bayswater Power Station was approved to be completed around the same time as the proposed closure of the Liddell Power Station in 2022. Liddell Power Station closed in April 2023. Both are owned by AGL Energy and consume coal from the same mine. The upgrade approval did not impose tighter air emission controls, however AGL claimed that the closure of Liddell would result in a net improvement in air quality. The upgrade increased the rated capacity of three turbines on the four generating units, increasing the capacity of each unit by whilst slightly decreasing the amount of coal consumed. As the OEM for AGL's Bayswater Power Station in the New South Wales Hunter Valley, Toshiba supplied and installed upgraded turbine steam path equipment and completed generator rewinds at Bayswater to increase output by 25MW per unit. The upgrade was completed on three out of the four Units with Unit 1 remaining at its original capacity.Planned Closure
In February 2022, AGL Energy announced that the Bayswater Power Station will close between 2030 and 2033 inline with AGL Energy's Climate Transition Action Plan.Plant information
Boilers
- Steam pressure:
- Steam temperature:
- Height:
Turbine & Turbo alternators
- Number in use: 4
- Manufacturer: Tokyo Shibaura Electric Company, Limited, Japan.
- Operating speed 3,000 rpm
- Alternator voltage: 23 kV
- Rating:
- * 1x
- * 3x
- Length:
- Weight:
- Stages on each turbine:
- * 1x High Pressure Turbine
- * 1x Intermediate Pressure Turbine
- * 2x Low Pressure Turbines
Turbine house
- Length:
- Height:
- Width:
Emission stacks
- Height:
- Diameter at base:
- Diameter at top:
Cooling towers
- Height:
- Diameter at base:
- Diameter at top: