Link budget
A link budget is an accounting of all of the power gains and losses that a communication signal experiences in a telecommunication system; from a transmitter, through a communication medium such as radio waves, cables, waveguides, or optical fibers, to the receiver. It is an equation giving the received power from the transmitter power, after the attenuation of the transmitted signal due to propagation, as well as the antenna gains and feedline and other losses, and amplification of the signal in the receiver or any repeaters it passes through. A link budget is a design aid, calculated during the design of a communication system to determine the received power, to ensure that the information is received intelligibly with an adequate signal-to-noise ratio. In most real world systems the losses must be estimated to some degree, and may vary. A link margin is therefore specified as a safety margin between the received power and minimum power required by the receiver to accurately detect the signal. The link margin is chosen based on the anticipated severity of a communications drop out and can be reduced by the use of mitigating techniques such as antenna diversity or multiple-input and multiple-output.
A simple link budget equation looks like this:
Power levels are expressed in, Power gains and losses are expressed in decibels, which is a logarithmic measurement, so adding decibels is equivalent to multiplying the actual power ratios.
In radio systems
A link budget equation including the key effects for a wireless radio transmission system, expressed logarithmically, might look like:where:
The path loss is the loss due to propagation between the transmitting and receiving antennas and is usually the most significant contributor to the losses, and also the largest unknown. When transmitting through free space, it can be expressed in a dimensionless form by normalizing the distance to the wavelength:
When substituted into the link budget equation above, the result is the logarithmic form of the Friis transmission equation.
In some cases, it is convenient to consider the loss due to distance and wavelength separately, but in that case, it is important to keep track of which units are being used, as each choice involves a differing constant offset. Some examples are provided below.
These alternative forms can be derived by substituting wavelength with the ratio of propagation velocity divided by frequency, and by inserting the proper conversion factors between km or miles and meters, and between MHz and Hz.
The gain of both the transmitting and receiving antennas is affected by the antenna's directivity. For example, antennas can be isotropic, omnidirectional, directional, or sectorial, depending on the way in which the antenna power is oriented.
- Isotropic antennas radiate power equally in all directions.
- Omnidirectional antennas distribute the power equally in every direction of a plane, so the radiation pattern has the shape of a sphere squeezed between two parallel flat surfaces. They are widely used in many applications, for instance in WiFi Access Points.
- Directional antennas concentrate the power in a specific direction, called the bore sight, and are widely used in point to point applications, like wireless bridges and satellite communications.
- Sector antennas concentrate the power in a wider region, typically embracing 45º, 60º, 90º or 120º. They are routinely deployed in Cellular towers.
Line-of-sight vs non-line-of-sight transmission
In non-line-of-sight links, diffraction and reflection losses are the most important since the direct path is not available. Building obstructions such as walls and ceilings cause propagation losses indoors to be significantly higher. This occurs because of a combination of attenuation by walls and ceilings, and blockage due to equipment, furniture, and even people.
- For example, a "2 by 4" wood stud wall with drywall on both sides results in about 6 dB loss per wall at 2.4 GHz.
- Older buildings may have even greater internal losses than new buildings due to materials and line of sight issues.
The attenuation of the signal is highly dependent on the frequency of the signal.
Further losses
In practical situations other sources of signal loss must also be accounted for, including:- The transmitting and receiving antennas may be partially cross-polarized.
- The cabling between the radios and antennas may introduce significant additional loss.
- Either antenna may have an impedance mismatch.
- Fresnel zone losses due to a partially obstructed line-of-sight path.
- Doppler shift induced signal power losses in the receiver.
- Atmospheric attenuation by gases, rain, fog and clouds.
- Fading due to variations of the channel.
- Multipath losses.
- Antenna misalignment.
Earth–Moon–Earth communications
- In practice, this limits the use of this technique to the spectrum at VHF and above.
- The Moon must be above the horizon in order for EME communications to be possible.
Voyager program
In waveguides and cables
Guided media such as coaxial and twisted pair electrical cable and radio frequency waveguides have losses that are exponential with distance.The path loss will be in terms of dB per unit distance. This means that there is always a crossover distance beyond which the loss in a guided medium will exceed that of a line-of-sight path of the same length.
In optical communications
The optical power budget in a fiber-optic communication link is the allocation of available optical power among various loss-producing mechanisms such as launch coupling loss, fiber attenuation, splice losses, and connector losses, in order to ensure that adequate signal strength is available at the receiver. In optical power budget attenuation is specified in decibel and optical power in dBm.The amount of optical power launched into a given fiber by a given transmitter depends on the nature of its active optical source and the type of fiber, including such parameters as core diameter and numerical aperture. Manufacturers sometimes specify an optical power budget only for a fiber that is optimum for their equipment—or specify only that their equipment will operate over a given distance, without mentioning the fiber characteristics. The user must first ascertain, from the manufacturer or by testing, the transmission losses for the type of fiber to be used, and the required signal strength for a given level of performance.
In addition to transmission loss, including those of any splices and connectors, allowance should be made for at least several dB of optical power margin losses, to compensate for component aging and to allow for future splices in the event of a severed cable.
Definitions:
- LT - Total loss
- α - Fiber attenuation
- L - Length of fiber
- Lc - Connector loss
- Ls - Splice loss
Long distance fiber-optic communication became practical only with the development of ultra-transparent glass fibers. A typical path loss for single-mode fiber is 0.2 dB/km, far lower than any other guided medium.